                您現在的位置:首頁 > 產品展示 > 化驗室PH/ORP計 > 手提/便攜式PH計 >手提式PH計
                手提式PH計

                手提式PH計

                簡要描述:
                PH-907 手提式PH計

                更新時間:2023-06-15

                訪問量:1901

                廠商性質:生產廠家

                生產地址:深圳市寶安區松崗街道東方社區5號棟9層

                PH-907  portable PH  INSTRUCTION
                 
                一、           Panel instruction
                l        ON/OFF : power switch
                l        MODE : function switch,
                Repeating:PH →MV→ TEMP  every press
                l        CALIB  : 7.00 calibration (6.86)
                l        SLOP   : 4.00 calibration (9.18、10.01)
                l        TEMP   :  temp compensation manually
                 
                 
                二、           Easy to operate
                1、Put the sensor in water , Turn the power on ,and LCD display current PH value ,if you need to calibrate , please check the calibration part of the manual. Wait for the reading to stabilize. It needs a few minutes to equalize the temp and all the condition .
                2、  Change a ORP sensor if you want to measure ORP in a solution ,THEN press the MODE key when you’ve changed your sensor。
                3、  For Temp compensation , you can easily turn the TEMP knob to the temp in witch the solution is。
                 
                三、           PH Calibration
                1、Put the clean PH sensor into buffer 7.00,a few agitation,wait for the reading to stabilize(suggest at least 5mins),turn CALIB knob to make the value reach 7.00 steadily。Recommend tuning slowly.
                2、Wash the sensor with distilled water and wipe it with soft tissue。
                3、Put the clean PH sensor into buffer 4.00(or 9 .18), agitate a little,wait for the reading to stabilize(suggest at least 5mins),turn CALIB knob to make the value reach 4.00(or 9.18) steadily。
                4、You may repeat the calibration process for 2-3 times for accuracy。
                 
                NOTE:1、When calibrate ORP sensor please select the right ORP standard。
                              2  pH sensor ‘s Temp range is  0-80℃
                              3、PH value is a parameter related to Temp, for accurate measure temp compensation is necessary . 
                4、storage for a long time ,such as weeks or months ,the sensor should be cleaned sufficiently
                BASIC CONsuitcase,9V battery ,combination PH sensor,buffer 7.00and4.00, manual。

                留言框

                • 產品:

                • 您的單位:

                • 您的姓名:

                • 聯系電話:

                • 常用郵箱:

                • 省份:

                • 詳細地址:

                • 補充說明:

                • 驗證碼:

                  請輸入計算結果(填寫阿拉伯數字),如:三加四=7
                国产成人91激情在线播放,亚洲欧美日韩成人网,国产精品免费午夜在线a,国产丝袜一区二区三区在线观看
                    <noframes id="tpbtt"><form id="tpbtt"><span id="tpbtt"><th id="tpbtt"></th></span></form>
                      <address id="tpbtt"><nobr id="tpbtt"><th id="tpbtt"></th></nobr></address>
                        <form id="tpbtt"><th id="tpbtt"><th id="tpbtt"></th></th></form><form id="tpbtt"><th id="tpbtt"><progress id="tpbtt"></progress></th></form>
                        <form id="tpbtt"></form>

                              <form id="tpbtt"><th id="tpbtt"><th id="tpbtt"></th></th></form>